Features:
LADN battery system is developed by the universal test of a new generation of battery test system, this LADN battery system has four modules, each module can be installed 1-8 independent programmable channel, each computer is allowed to hang 1-2 cabinets, completely independent between each unit, completely independent between channel (independent programming control).
Applications:
This LADN battery system measurement and control precision current: 0.05%RD ± 0.05%FS, voltage: 0.05%RD ± 0.05%FS. The range is: 5V/1-50mA supports constant current charging, constant current discharge, constant voltage charging, constant power discharge, static stand of lithium ion, sodium ion, nickel and cobalt and other battery working modes, and support negative voltage discharge, voltage, current oversize range protection.